Butterfly|Gate|Globe|Ball valve-China valve manufacturer and factory

CS11H Screw end float ball steam trap

CS11H Screw end float ball steam trapCS11H Screw end float ball steam trap
CS11H Screw end float ball steam trap

CS11H Screw end float ball steam trap Product introduction

 CS11H Screw end float ball steam trap continues dischargins saturation condensed water without accumulation,and so get the maximum thermal efficiency.when steam pressure changes,the ball  float can adjust the opening of valve seat whthout influence,and so CS11H Screw end float ball steam trap is stable whith automatic and manual releaser,and so its exhaust performance is good without airlock and working is smooth without noise

CS11H Screw end float ball steam trap specification

Size: DN15~DN50

Connection: RF, NPT,SW

Pressure: PN10, PN16, PN25,PN40
 

CS11H Screw end float ball steam trap material

No.                Part Name                                                   Materials                                        
1 Body WCB,WC6,SS304,SS316
2 Screw Plug 35,2Cr13
3 Screw Plug 35,2Cr13
4 Seat 2Cr13
5 Float Ball SS304
6 Screen SS304
7 Circlip A3
8 Bonnet A105
9 Sylphon SS304
10 Seat 2Cr13
11 Screw Plug 35,2Cr13


CS11H Screw end float ball steam trap parameter

Minimum Working Pressure 0.01MPa Maximum allowable temperature for cast steel 425℃
Minimum degree of supercooling ≈0 Working medium saturated vapour,condensed water
Maxmum allowable rate of back pressure 80% Exhaust plant stainless steel/alloy
Valve body.Cap WCB/304 Ball Float Stainless Steel
Valve seat 2Cr13/304 Filter Ball Stainless Steel


How does CS11H Screw end float ball steam trap work?

By the action of buoyance,the position of ball float changes with the water level of condesation water and adjust the opening of valve seat automatically,continue to discharge condensation water.When the condensation water stops,the ball float fall onto bottom by gravity,the close opening of drain valve.The opening of drain valve is below the water lever,and so the water is separated from steam automatically,and form water seal without steam leakage
 

CS11H Screw end float ball steam trap application

CS11H Screw end float ball steam trap is used for the steam heating equipment,condensation water recovery system and the place where needs removing condesation water at quick speed ,and so stop steam leakage effectively and obtains optimum heating.

 

CS11H Screw end float ball steam trap Related Products

Previous:CS41H Flanged free ball float steam trap

Next:FT44H Lever ball float steam trap


Shanghai Huixuan Valve&Pipe Co.,Ltd.   Address :No.720 Suide Road,Jiading district,Shanghai,China
English website :www.hxvalves.com       Tel:+86+17717520739   
 Email :info@shxvalve.com
  
Copyright © 2012  Shanghai Huixuan Valve&Pipe Co.,Ltd.

               BALL VALVE   PLUG VALVE  BUTTERFLY VALVE  CONTROL VALVE  JACKETED VALVE